Simplicity CIJ models may encounter display-related problems during use, generally showing the following problems:
- The screen is stuck, and the button does not respond.
- Occasionally unable to enter the main interface, always stay on the open interface.
- The response position is not accurate during the screen touch.
- The screen is not responsive after power-on (black screen).
For the above situations, the site can be implemented according to the following methods.
In the first case, the security interface
- Carry out the calibration according to the calibration guidelines.(1240 / 1280 Enter the password interface in the secure mode, perform the screen calibration; 1580 / 1880 enter the secure mode interface for execution); and then check whether the problem is resolved.
- If the problem cannot be solved after calibration, enter the Safe Mode upgrade menu and use Safe Mode to upgrade the printer software.
- If the above operation is invalid, please replace the SD card first;
- If the motherboard fails, replace the motherboard.
- If the display fails, replace the display.
In the second case, the security interface cannot be accessed
- Check whether the display screen data cable connection is normal, and plug it in again.
- May the screen touch fault, replace the display component.
- Change the motherboard.
In the third case, the power-on screen is not responsive
- Check whether the main board indicator light is lit; whether the fan is working normally;
- Reinstall the SD card.
- Replace the SD card.
- If the fault is still correct, replace the motherboard.
Possible Spares and Spare Parts Number:
| Spare parts \ model | 1240 | 1280 | 1580 | 1880 |
| SD block | 383552 | 383552 | 611242 | 611242 |
| mainboard | 383551 | 383551 | 613594(IP55)/ 611395(IP65) | 611586 |
| Display component | 383555 | 383555 | 613615 | 611576 |
If you encounter any screen problem on the site, whether solved or not, please feedback the problem to the channel technical support staff.